Apc Battery Backup Ups 1.5kva

Apc Battery Back-Up 1.5KVA UPS

Keys Features

Run Time For Load                        865W,            3m

Max. Capacity Used                        100%

Output power capacity                  865Watts / 1.5kVA

Output Connections                      (5) IEC 320 C13 (Battery Backup)

(2) IEC Jumpers (Battery Backup)

(5) IEC 320 C13 (Surge Protection)

Nominal Output Voltage             230V

Nominal Input Voltage                230V

Input Connections                         IEC-320 C14

264,600.00

Out of stock

APC Power-Saving Back-UPS Pro 1500, 230V

High Performance Computer and Electronics UPS for Premium Power Protection

Includes: CD with software, Qty 1- Detachable IEC Power Cord, Telephone Cable, USB cable, User Manual, Warranty card

 

  • Adjustable voltage sensitivity

Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

  • Adjustable voltage-transfer points

Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

  • Audible alarms

Provides notification of changing utility power and UPS power conditions

  • Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

  • Battery failure notification

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

  • Battery replacement without tools

Enables fast battery replacement, lowering Mean Time to Repair (MTTR).

  • Battery-protected and surge-only outlets

Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

  • Boost and Trim Automatic Voltage Regulation (AVR)

Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

  • Building Wiring Fault Indicator

This LED informs users of potentially dangerous wiring problems in the wall circuit.

  • Cold-start capable

Provides temporary battery power when the utility power is out.

  • Dataline surge protection

Provides protection of connected equipment from power surges on the data lines.

  • Disconnected battery notification

Warns when a battery is not available to provide backup power.

  • Extendable Run Time

Meet long run-time needs.

  • Green mode

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

  • Hot-swappable batteries

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

  • Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

  • LCD graphics display

Text and mimic diagrams that display modes of operation, system parameters and alarms.

  • Power-saving outlets

Automatically cuts power to idle equipment to conserve electricity.

  • Resettable circuit breaker

Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)

  • Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

  • Serial connectivity

Provides management of the UPS via a serial port.

  • Telephone dataline surge protection

Provides protection of connected equipment from power surges traveling on telephone lines.

  • Transformer-block spaced outlets

Protect equipment with input transformer blocks without blocking access to other receptacles.

  • USB connectivity

USB compatibility and connectivity ensures quick and easy installation of the free PowerChute Personal Edition Software.

  • User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

 

Back-UPS Pro Features & Benefits

Serviceability

Simple battery replacement

Increases UPS availability by allowing quick, easy battery replacement.

Resettable circuit breaker

Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)

Safety

Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Manageability

Disconnected battery notification

Warns when a battery is not available to provide backup power.

LCD Status Display

Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

USB connection

Use your PC to access additional power protection and management features for your UPS via a USB Port.

Audible alarms

Provides notification of changing utility power and UPS power conditions

Customizable voltage-transfer points

Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.

Green mode

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Cold-start capable

Provides temporary battery power when the utility power is out.

Customizable voltage sensitivity

Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.

Battery failure notification

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Boost and Trim Automatic Voltage Regulation (AVR)

Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Transformer-block spaced outlets

Protect equipment with input transformer blocks without blocking access to other receptacles.

Protection

Battery and surge protected outlets

Back up and protect your hardware and data during power outages, surges and spikes.

Dataline surge protection

Provides protection of connected equipment from power surges on the data lines.

Surge only outlets

Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

Marketing features

Boost Automatic Voltage Regulation (AVR)

Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.

Battery-protected and surge-only outlets

Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Categories: ,

Technical Specifications

Output

Max Configurable Power (Watts)          865Watts / 1.5kVA

Output Frequency (sync to mains)        50/60Hz +/- 3 Hz

Load Crest Factor               3 : 1

Topology                               Line Interactive

Waveform type                   Stepped approximation to a sinewave

Transfer Time                                  10ms typical : 12ms maximum

Input

Input frequency                              50/60 Hz +/- 3 Hz (auto sensing)

Input voltage range for main operations                     176 – 294V

Input voltage adjustable range for mains operation            156 – 300V

Number of Power Cords               1

Batteries & Runtime

Battery type

Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof

Typical recharge time                                8hour(s)

Expected Battery Life (years)                  3 – 5

RBC Quantity                                               1

Battery Volt-Amp-Hour Capacity           187

 

Communications & Management

Interface Port(s)                 Optional Simple Signalling RS232 cable, USB

Control panel                       Multi-function LCD status and control console

Audible Alarm

Alarm when on battery: distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering

Surge energy rating           441Joules

Data Line Protection

Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line – 10/100/1000 Base-T Ethernet (RJ-45 connector)

Filtering

Full time multi-pole noise filtering :10% of IEEE surge let-through : zero clamping response time: instantaneous

Physical

Maximum Height                301MM, 30.1CM

Maximum Width                112MM, 11.2CM

Maximum Depth                380MM, 38.0CM

Net Weight                          12.7KG

Color                                      Black

Master Carton Units          1.0

SCC Codes                             1073130426874 8

Environmental

Operating Temperature                0 – 40 °C

Operating Relative Humidity       0 – 95 %

Operating Elevation                       0-9000meters

Storage Temperature                    -15 – 45 °C

Storage Relative Humidity           0 – 95 %

Storage Elevation               0-15000meters

Audible noise at 1 meter from surface of unit           45.0dBA

Conformance

Approvals                  A-tick, C-tick, CE, GOST, GS Mark, Telepermit, TUV

Equipment protection policy

Lifetime: 200000 AUD, Lifetime: 150000 Euros, Lifetime: 75000 GBP

Standard warranty

2 years

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Apc Battery Backup Ups 1.5kva”

There are no reviews yet.

Delivery & Returns

Delivery Information

Foretec delivers between 1-3 working days in Abuja. Please check exact dates in the Checkout page

Pickup Location

BSG 39 Banex Plaza, Aminu Kano Crescent Wuse 2 Abuja

Return Policy
 
Foretec accepts free return within 14 days for other eligible items.

SHOPPING CART